Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 09, 2021 SAM #7069
SOURCES SOUGHT

W -- Rental/Maintenance of one (1) 6K, 3 Ton, Counterbalanced Forklift.

Notice Date
4/7/2021 9:46:25 AM
 
Notice Type
Sources Sought
 
NAICS
532490 — Other Commercial and Industrial Machinery and Equipment Rental and Leasing
 
Contracting Office
PORTSMOUTH NAVAL SHIPYARD GF PORTSMOUTH NH 03801-5000 USA
 
ZIP Code
03801-5000
 
Solicitation Number
3904021RC10322
 
Response Due
4/7/2021 8:59:00 PM
 
Archive Date
04/22/2021
 
Point of Contact
Ronald Lizotte, Phone: 207-438-4930, Fax: 207-438-4193
 
E-Mail Address
ronald.lizotte@navy.mil
(ronald.lizotte@navy.mil)
 
Description
Rental/Maintenance of one (1) 3 Ton Forklift. FORK LENGTH: 48"" Enclosed cab with heater, defrost, and wipers. POP: 05/17/2021-04/18/2022. 48 Weeks Option:�Rental/Maintenance of one (1) 3 Ton Forklift. FORK LENGTH: 48"" Enclosed cab with heater, defrost, and wipers. POP: 04/19/2022-05/03/2022. 2 Weeks FORKLIFT RENTAL STATEMENT OF WORK REQUIREMENTS:� CAPACITY/TYPE: (1) 6k (3-ton) COUNTERBALANCED FORKLIFTS (minimum) POWER TYPE: Diesel fueled LIFT HEIGHT: 126"" MAX COLLAPSED HEIGHT: 92"" TOTAL LENGTH: NOT TO EXCEED 13'� FORK LENGTH: 48"" � STANDARD REQUIREMENTS (ALL FORKLIFTS): - Shall be no older than five years - Manufacturer�s data plate containing, at a minimum, make, model, fork and mast type, and serial number - Serviceable pneumatic or solid pneumatic tires - Enclosed cab with heater, defrost, and wipers - Integral side-shift and hydraulic fork positioners - Engine block heater - Lifting and tie-down provisions for lifting by crane without additional special handling gear (Lifting and tie-down points shall be clearly marked) - Safe working load and forklift weight clearly labeled in view of operator, normally on the mast crossbar using largest lettering size that fits (Labeling tape acceptable) - Center of gravity clearly marked on side of forklift - Light package to include two front and one rear working light and two brake/tail/back-up combination lights - Operator controls shall be properly and clearly marked - UL safety rated (DS or LPS) with type designation labels applied to both side and rear of forklift Equipment shall be delivered in fully functional, safe operating condition.� A joint inspection of each forklift shall be performed by the Contractor and a shipyard licensed operator using attachment (1) of this contract before the unit is accepted by the Government. The rental period does not begin until the government has accepted the forklift.� The contractor shall notify the Contracting Officer�s Representative (COR) or Technical Point of Contact a minimum of 48 hours prior to delivery of units. The contractor shall be responsible for all preventative maintenance and repairs not arising out of abuse or negligence by the Government.� The government shall be responsible for daily fluid level checks; however, the contractor shall be responsible for adding fluids to the equipment to ensure the loss of fluid is not due to a more serious mechanical issue.� All service shall be provided within four (4) hours of notification to the contractor.� In the event the equipment cannot be returned to service within twenty-four (24) hours, a replacement shall be provided by the contractor at no charge to the Government.� Contractor shall validate all completed repairs by either signing the appropriate MHE Inspection Sheet, attachment (2) or providing a completed and signed repair order. The contractor shall provide liquid spill protection to the ground surface during all maintenance and repairs. Any/all spills shall be contained and cleaned up prior to leaving the site.� If during use, a liquid spill is caused by a broken or leaking line or some other system on the contractor�s equipment, the installation spill team will be alerted to contain the spill until the contractor can make the necessary repairs.� It shall be the responsibility of the contractor to reimburse the Government for containing the spill. If fluid leaks become frequent the government may request to have the equipment removed from the shipyard and replaced with a different forklift.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/7f0a61e1ec3f466e855dd5b23df2b77e/view)
 
Place of Performance
Address: Kittery, ME 03904, USA
Zip Code: 03904
Country: USA
 
Record
SN05965555-F 20210409/210407230118 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.