SOLICITATION NOTICE
42 -- Quaestor 8000 Standard
- Notice Date
- 6/3/2025 5:14:42 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334519
— Other Measuring and Controlling Device Manufacturing
- Contracting Office
- W6QM MICC-FT DRUM FORT DRUM NY 13602-5220 USA
- ZIP Code
- 13602-5220
- Solicitation Number
- W911S225U0848
- Response Due
- 6/12/2025 2:00:00 PM
- Archive Date
- 06/03/2026
- Point of Contact
- James Ferraro, Phone: 5735632910, Joy Davis, Phone: 3157729900
- E-Mail Address
-
james.a.ferraro.civ@army.mil, joy.l.davis18.civ@army.mil
(james.a.ferraro.civ@army.mil, joy.l.davis18.civ@army.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- Salient Characteristics:001: Quaestor 8000 Standard: (R63260) Must be able to test Drager PSS 7000SCBA?s and Drager Pas-Colt Escape paks Must be a fully automatic test instrument for thetesting of full-face masks, compressed air breathing apparatus and closed-circuit breathingapparatus Must have training on new equipment provided by seller Must have an externalmicrophone Must have a gauge holder Must have a low-pressure measuring point Musthave a test head with gel face Must have a storage area for components Must have a CPSfilling connection Must have a medium pressure extractable inlet and a rotatable outletMust have a high-pressure inlet and outlet Must have a breathing volume of at least 134L/min The breathing frequency of the artificial lung must be at least 5 to 38 strokes a min.Must have a pressure sensor accuracy less than 1 according to DIN EN 837 Must havepermitted air pressure no less than 22 inHg and no more than 36 inHg Must weigh at least45 lbs. Must have a permitted low storage temperature of -20F and a permitted high storagetemperature of 136F Must have a high-pressure range of at least 350 bar Must have amedium pressure range of at least 25 bar Must have a low-pressure range of at least -40 to+30 mbar Must have adapters for 4500 psi systems and adapters for 3000 psi escapedevices Must have a connection for external microphone and external microphone must beprovided Must have a 24V power adapter for 110/230V power supply.002: Case Quaestor (3712635)003: Set Q6/8k bypass relief valve (3731941)004: Bar module, Spare set 200 bar module with output. (R58367)005: Quaestor 8000 Training
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/6d7cc950e15344b8b42ac107a3e2eaa0/view)
- Place of Performance
- Address: James FerraroBldg. 773 Indiana Ave.Fort Leonard Wood, MO 65473 65473
- Zip Code: 65473
- Zip Code: 65473
- Record
- SN07463982-F 20250605/250603230049 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |