SOURCES SOUGHT
66 -- - 623 (Activation NCO19LAB) Biofire FilmArray Torch System, PKG 36 CHIP-IN, SEPG 491996 EER 257002
- Notice Date
- 6/27/2025 9:20:30 AM
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- NETWORK CONTRACT OFFICE 19 (36C259) Greenwood Village CO 80111 USA
- ZIP Code
- 80111
- Solicitation Number
- 36C25925Q0579
- Response Due
- 7/7/2025 3:00:00 PM
- Archive Date
- 08/06/2025
- Point of Contact
- Devin Reichert, Contract Specialist, Phone: (303) 712-5773
- E-Mail Address
-
Devin.Reichert@va.gov
(Devin.Reichert@va.gov)
- Awardee
- null
- Description
- DESCRIPTION REQUEST FOR INFORMATION / SOURCES SOUGHT INQUIRY THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. The Department of Veterans Affairs Network Contracting Office (NCO) 19, Rocky Mountain Acquisition Center (RMAC) is seeking information and sources that can provide Activation Biofire FilmArray 4 Torch System, Brand Name or Equal To for James Mountain Inhofe VA Medical Center 440 S. Houston Avenue Tulsa, OK 74127. The Equal To offer must meet the following salient characteristics: System Type: Automated In Vitro Diagnostic Device Performance Features: One Hour Sample Run Time System Base with Touch Screen and Barcode Scanner Automatic analysis with end-of-run interpretive reports Optics and Imaging: Single color optics module: 475nm excitation, 545nm emission, and sensor imaging Scalability and Throughput: Scalable configuration allows customized throughput Compatible with six syndromic BIOFIRE® FILMARRAY® Panels. Reduced footprint provides up to six times the throughput per square foot of laboratory bench space Data management: Automation includes LIS connectivity and random-access operation Temperature Control: Operating temperature 15°C to 30°C Peltier devices: Ambient to 100°C Ramp rate from 0.1 0.5°C /sec on melt Operations Specification: 15°C to 30°C @ 20 to 80% relative humidity (non-condensing) -16m to 3048m Indoor use only System Interface/Hardware: Capacitive Touch Screen Interface 512 GB Hard Drive GB RAM CPU Dimensions and Weight: Dimensions System Base: 18 x 29 x 11.5 in (45.8 x 73.7 x 29.2 cm) (W x D x H) Module Height 4.5 in (11.4 cm) Max Height 34 in (86.4 cm) max height Weight: (Maximum total) Approximately 268 lbs (121.6 kg) System Base 36 lbs (16.3 kg) Modules 15 lbs (6.8 kg) each Duplex (Module enclosure) 6.5 lbs (~3 kg) each QTY: 1 The contractor must provide all parts required to meet the salient characteristics required: One (1) Activation Biofire FilmArray 4 Torch System, Brand Name or Equal To- Period of Performance Estimated based on manufacturing and delivery lead time 11-10-2025 - 1-10-2026 QTY Unit of Issue Item Description 1 EA Biofire FilmArray Torch 4 System VC - TORCH 4 - Ignited by FIREWORKS, Brand Name or Equal To 1 EA Connection Service Vilink, Brand Name or Equal To 1 EA Connection Serv Customer Remote Solution, Brand Name or Equal To The NAICS code is 325413 In Vitro Diagnostic Substance Manufacturing and Small Business Size Standard is 1250 Employees.� In response to this announcement, please provide the information below. If this information is not provided, then it will be assumed the entire requirement cannot be met: NAICS Code: 325413 Company Name: Address: UEI (Unique Entity ID) Number: Contact Name: Phone No.: Email: Business Size Information - Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HUBZone Woman Owned Certified Service-Disabled Veteran Owned Small Veteran Owned Small Business Large Business FSS/GSA Contract Holder: Yes No FSS/GSA Contract Number: Effective Date/ Expiration Date: Proposed solution is listed and available on the above FSS/GSA Contract: Yes No Federal Acquisition Regulation (FAR) Market Rearch Questions: Buy American Act (FAR 52.225) What percentage of the proposed product (including leases) is a: Domestic end product? _____________ (%) Foreign end product? _______________ (%) Questions for Small Businesses ONLY: Limitations on Subcontracting (FAR 52.219-14) What percentage of the work would be subcontracted to another company? ________ If > 0, what is company s business size: __________ If subcontracting, what added value do you offer (FAR 52.215-23): _______________________________ Nonmanufacturer Rule (FAR 52.219-33): Does your company manufacturer these proposed items? [� ] yes [� ] no Does your company exceed 500 employees? [� ] yes [� ] no If yes, list # of employees: _________ Does your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [� ] yes [� ] no Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [� ] yes [� ] no Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [� ] yes [� ] no If yes, what is the manufacturer s name? ________________ The information submitted shall contain the company s business size status. This is a request for information and sources only, which may or may not lead to a future solicitation. This is not a request for quote (RFQ). No questions will be answered. The VA will not pay for any information received resulting from this sources sought notice. Requests for copies of a solicitation shall not be honored or acknowledged. Information should be forwarded to the Contracting Officer. If your organization can provide all services of this potential requirement and is interested in this opportunity, please respond to Devin Reichert, Devin.Reichert@va.gov, Contracting Specialist, Department of Veterans Affairs, NCO 19, 6162 S. Willow Drive, Suite 300, Greenwood Village, Colorado 80111 and NCO19lab@va.gov � with a statement describing your capabilities and completed table above. The capability statement shall include a point of contact, complete mailing address, telephone number, email address and state the company s business size status. The deadline for this information to be received is 09:00 AM Mountain Time, 07/03/2025. Sources Sought Notice Sources Sought Notice Page 5 of 5 *= Required Field Sources Sought Notice Page 1 of 5
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/1bac94f320554798afcab847e96cbf79/view)
- Place of Performance
- Address: Department of Veterans Affairs James Mountain Inhofe VA Medical Center 440 S. Houston Avenue, Tulsa, OK 74127, USA
- Zip Code: 74127
- Country: USA
- Zip Code: 74127
- Record
- SN07492483-F 20250629/250627230046 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |