Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 01, 2025 SAM #8618
SOURCES SOUGHT

66 -- GLERL Pro-Oceanus PCO2 Sensors

Notice Date
6/29/2025 2:53:53 PM
 
Notice Type
Sources Sought
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
DEPT OF COMMERCE NOAA SEATTLE WA 98115 USA
 
ZIP Code
98115
 
Solicitation Number
145025250060IV
 
Response Due
7/9/2025 9:00:00 PM
 
Archive Date
07/10/2025
 
Point of Contact
Isabel Vigil, Phone: 3035788031
 
E-Mail Address
isabel.vigil@noaa.gov
(isabel.vigil@noaa.gov)
 
Small Business Set-Aside
NONE No Set aside used
 
Description
Notice Number: 145025250060IV Notice Type: Sources Sought Synopsis Title: Pro-Oceanus Mini CO2 & CO2-Pro CV Submersible pCO2 Sensors Response Date: This is a SOURCES SOUGHT SYNOPSIS and is not a pre-solicitation announcement. The purpose of this Market Research and Sources Sought Notice is to gain knowledge of potential qualified businesses, which could include Small Business, HUBZone, 8(a), Service Disabled Veteran Owned, Women Owned Small Business firms and even Large Businesses offering domestically manufactured products that meet the required specifications. Responses to this Sources Sought Synopsis will be used by the Government in making appropriate acquisition decisions. The National Oceanic and Atmospheric Administration (NOAA), Oceanic and Atmospheric Research (OAR), Great Lakes Environmental Research Laboratory (GLERL) is a multidisciplinary environmental research laboratory that provides scientific understanding to inform the use and management of Great Lakes and coastal marine environments. The GLERL uses sensors to collect and monitor the CO2 and acidification levels of the Great Lakes and provide data for HAB analysis. As atmospheric CO2 increases, the availability of dissolved inorganic carbon (DIC) is shifting within aquatic systems causing the pH to drop. Due to the multi-faceted nature of the DIC system, the GLERL requires a submersible pCO2 sensor like the Pro-Oceanus Mini CO2 in order to document the impacts or potential shifts in phytoplankton species composition and abundance. INTENDED USE/PURPOSE: The Mini CO2 instrument uses infrared detection to measure the partial pressure of CO2 gas dissolved in liquids with a range from 0-1000 ppm up to 0-100%. The instruments are compact, lightweight, plug and play sensors; and measure total dissolved gas pressure (TDGP). The housing is rated to 6000 dbar of hydrostatic pressure, and is resistant to most corrosive liquids. The CO2-Pro� CV instrument measures the partial pressure of CO2 gas dissolved in water using infrared detection. Standard ranges from 0-600 ppm up to 0-10,000 ppm as well as custom rages are available that cover the full spectrum of pCO2 needed for accurate measurement of ocean, coastal, riverine, and lake CO2 levels. These are the only known instruments that can meet the Government�s needs, and this notice�s intent is to identify any other products that meet the full requirements listed below. SPECIAL REQUIREMENTS/ESSENTIAL SALIENT FEATURES: Mini CO2 Sensor Performance: CO2 Measurement Ranges: 0-2000 ppm CO2, by volume; 0-5000 ppm; 0-1% (10,000 ppm); 0- 100% Total Dissolved Gas Pressure: 0-2 bar Accuracy: pCO2: � 2% of max range TDGP: � 1% Equilibration rate (t63): 3 minutes Resolution: 0.1% of max range Physical Specifications: Length: 28 cm (11 in) Diameter: 5.3 cm (2.1 in) Weight - Air: 0.53 kg (1.2 lbs) Weight - Water: -0.06 kg (-0.1 lbs) Housing Material: Acetal Plastic / Titanium Depth Rating: 0 - 600 m (Plastic); Up to 6000 m (Titanium) Water Temperature: 0� to 40� C Electrical: Input voltage: digital: 7 - 24 VDC; analog: 12 - 24 VDC Power consumption: 85 mW (7 mA @ 12 V) Data output: digital: RS-232, ASCII CSV; analog: 0-5 V or 4-20mA Sample rate: 2 seconds (variable rate with logger/controller) Optional Accessories: Titanium housings: Rated up to 6000 m depth Internal battery power External battery pack: 19, 76 or 134 Amp-hour capacity Water-pumped head: Reduce biofouling and improve response rate Mooring cage or frame with instrument brackets Pigtail Cables with Locking Sleeves: 5, 10, 25, 50 meters, or longer Applications: Aquaculture monitoring of dissolved CO2 for fish and shellfish health Coastal zone CO2 fluxes Algae to fuel bioreactor feedback control Groundwater and well water monitoring Carbon budget studies for lakes and rivers Carbon capture storage monitoring of aquifer and surface water levels of pCO2 Wastewater greenhouse gas emissions Ocean glider and profiler missions CO2-Pro� CV Sensor Performance: Accuracy CO2 concentration �0.5% Resolution CO2 concentration 0.01 ppm Zero drift automatic zero compensation Equilibration time (t63) 50 seconds (with pumped head Standard range 0-600 ?atm 0 - 1000 ?atm 0 - 2000 ?atm *other ranges available Physical: Length 38 cm (15 in) Diameter 10 cm (4 in) Weight Air: 2.8 kg (6.2 lbs) Water: 0 kg Housing Acetal Plastic or Titanium Depth 0-600 meters (Plastic) 0-2000 meters 0-4000 meters 0-6000 meters (Titanium) Water Temperature 0� to 30� C (Standard) -2� to 20� C (Arctic) 15� to 40� C (Tropical) Electrical: Input voltage 10 - 18 VDC Power consumption 3 W (9 W during warmup) w/Optional Water Pump 4 W (10 W during warmup) Data output RS-232, ASCII format, 0-5 V or 4-20mA optional Sample rate 1 second (variable rate with logger/controller) Optional Accessories: Water-Pumped Interface Head Reduces biofouling and improves response rate Internal Battery Power External Battery Pack 76, 134, or 247 Amp-hour capacity Seabird Water Pump with cable 5P (Plastic) or 5T (Titanium) Mooring cage or frame with instrument brackets Pigtail Cables with Locking Sleeve 5, 10, 25, or 50 meters DELIVERY SCHEDULE: Deliver by 60 days after date of award. The North American Industry Classification Code (NAICS) is 334519 with a size standard of 600 employees. Interested firms shall provide, in writing, a brief narrative (no more than 3 pages in length) and documentation to support your firm�s capability and experience meeting the requirements herein and include your firm�s name, address, point of contact, telephone number, UEID Number, CCR CAGE Number, business type and size (i.e., small, large, non-profit, educational, etc.). Any response that does not include this information will not be considered. The Government will review your response to determine if your firm has the experience, knowledge and capability to provide the items as specified above. This request for information does not constitute a commitment, implied or otherwise, that a procurement action will be issued. Nor does this request for information constitute a commitment, implied or otherwise, that any procurement action may be issued for the Government�s requirements. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of the submission of contractor�s information. The Government shall not be liable for or suffer any consequential damages for proprietary information not properly identified. Proprietary information will be safeguarded in accordance with the applicable Government regulations. All contractors doing business with the Government are required to be registered and active with the System for Award Management (SAM) website. NOTE: THIS SYNOPSIS IS NOT CONSIDERED A REQUEST FOR PROPOSAL BUT A REQUEST FOR INFORMATION ONLY. No solicitation document is available. No contract will be awarded based on responses received to this notice.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/d503a7b4f4b24d038aaafd468424f6bd/view)
 
Place of Performance
Address: Muskegon, MI, USA
Country: USA
 
Record
SN07492612-F 20250701/250629230039 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.