Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 19, 2025 SAM #8636
SOURCES SOUGHT

99 -- Load Banks Setting Adjustments

Notice Date
7/17/2025 6:17:44 AM
 
Notice Type
Sources Sought
 
NAICS
335312 — Motor and Generator Manufacturing
 
Contracting Office
BATTELLE ENERGY ALLIANCE�DOE CNTR Idaho Falls ID 83415 USA
 
ZIP Code
83415
 
Solicitation Number
INL-25-014
 
Response Due
8/14/2025 10:59:00 PM
 
Archive Date
08/29/2025
 
Point of Contact
Fabiola Sorenson, Chase Egbert
 
E-Mail Address
fabiola.sorenson@inl.gov, chase.egbert@inl.gov
(fabiola.sorenson@inl.gov, chase.egbert@inl.gov)
 
Description
INTRODUCTION Battelle Energy Alliance, LLC (BEA) Management & Operating Contractor of the U.S. Department of Energy (DOE) owned Idaho National Laboratory (INL), is seeking an Expression of Interest (EOI) from prospective offerors who would like to provide services. The Materials Fuels Complex (MFC) has a Hot Fuel Examination Facility (HFEF) where there are two stand-by diesel generators (SDG) to provide power in case of a power outage. Each generator has a variable load bank (VLB) connected in parallel with the loads of the facility. Having these two VLBs in combination with the loads of the facility ensures constant output power from the generators. During periods of running the load banks with the generators, the site load correction did not step down to shed load as building load levels picked up. This causes the load to not shed when the selector switch is at higher selected positions. After troubleshooting and contacting previous technicians on this issue, it was determined that the VLBs will need to be reprogramed. BACKGROUND Currently, the load banks are set to a maximum load of 400kW, but we need them to be set to 200kW. To avoid overloading, the load banks are administratively controlled and locked to restrict full utilization. BEA is seeking a subcontractor to reprogram the load banks to the correct settings. The subcontractor will be required to reprogram the VLB controlling software by modifying the maximum threshold load limits from 400kW to 200kW. This involves accessing the controlling software for the VLBs (Sigma 2 Diagnostics or similar), unlocking the settings, and digitally adjusting the maximum limits for both VLBs (S-LB-003 and S-LB-004). After making these changes, the subcontractor will conduct a load test on the generators to ensure neither VLB exceeds 200kW when set to maximum. SUBMITTAL REQUIREMENTS Interested firms are requested to provide expressions of interest via email by close-of business on 08/14/2025. Responses must include sufficient written information to clearly show how the responder will complete the service listed in section 2 of this request. Note that responses must be no more than three (3) pages in length in PDF format. Only select respondents, as determined by BEA, will receive an invitation to participate in the anticipated Request for Proposal (RFP) solicitation. If you have questions, or need additional information, please contact Fabiola Sorenson, Contract Specialist, via email at fabiola.sorenson@inl.gov the subject line �Load Banks Setting Adjustments�, any technical questions must be submitted in writing via email. PROPRIETARY INFORMATION Because information received in response to this EOI may be business sensitive or proprietary to the responding party, respondents must mark information in their responses accordingly.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/b70ac1feecfd4a46bd3cb2d7fe4ee633/view)
 
Place of Performance
Address: Idaho Falls, ID 83415, USA
Zip Code: 83415
Country: USA
 
Record
SN07515076-F 20250719/250717230100 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.